Technology Torque Vector Torque Vector Flux Vector AC Servo Digital DC Analog DC
             
Drive Series Quix (QX3) ARTDrive G (AGy) ARTDrive (AVy) ARTDrive S (XVy) Typact-D (TPd32) Typact-A (TPy2&3)
             
Specifications...            
Power .5 - 5HP 7.5 - 150HP 1 - 800HP 1 - 200HP 5 - 2000HP 1/8 - 2000HP
(Tpy2 & Tpy3)
Voltage 400 - 460, 3ph 230 - 600, 3ph 230 - 600, 3ph 230 - 460, 3ph 230 - 690, 3ph 115 - 415, 1ph (Tpy2)
220 - 690, 3ph (Tpy3)
             
Speed regulation (accuracy) (.5 - 1%) (0.5 - 1%) 0.01% * absolute 0.01% * 1% (varies by tach)
Controllable Speed Range 20:1 50:1 10,000:1** infinite with sin enc 10,000:1** -
Communications RS485***, Modbus RTU, DeviceNet, Profibus DP, CanOpen RS485***, Modbus RTU, DeviceNet, Profibus DP, CanOpen RS485***, Modbus RTU, DeviceNet, Profibus DP,
CanOpen
RS485***, Modbus RTU, DeviceNet, Profibus DP, CanOpen, FastLink RS485***, Modbus RTU, DeviceNet, Profibus DP, Interbus S, CanOpen -
Applications...            
Centrifigal Pumps & Fans X X        
Conveyors X X X X X X
Converting, Extruders, Winders X X X X X X
Material Handling X X X X X X
Machine Tool X X X X X X
Packaging, Positioning X X X X X  
Test Stands X X X X X X
Embedded PLC Controllers     X X X  
Wire & Cable, Wire Draw   X X X X X
Tube Mills, Rolling Mills   X X X X X
Punch Presses X   X X    
Glass X X X X X X
Paper X X X X X X

X = Drive is capable of use and is commonly used in the specified application(s)

*W/ sin encoder, 0.2% w/ DE

**W/ sin encoder, .1000:1 w/ DE

***RS485 port is used for programming (PC) and control (Modbus or S LINK 3) Quix2000 and Agy use Modbus RTU Avy, Xvy, and Tpd32 use
     S LINK 3 (similar to modbus RTU)